Watch Amplitude Decay Calculator for Power Reserve and Balance Wheel Health

The first and only free amplitude decay calculator for mechanical watch movements. Three modes: Quick (full wind vs current reading), Positional (dial-up vs crown-up spread assessment), and Multi-Session (log up to 8 readings across the power reserve cycle). Automatically detects overbanking risk above 330°, low-reserve stopping risk below 180°, and abnormal positional spread above 60°. Uses verified amplitude thresholds from Rotate Watches, H2i.ch, and SJX Watches. AWCI-referenced standards for US watchmakers.

📈 Multi-Session Session Logging 🚨 Overbanking Risk Alert 🆕 Positional Spread Analysis ⏳ Decay Rate deg/hour 📚 AWCI-Referenced Thresholds 📄 PDF Bench Report
270-310°
Healthy DU amplitude (modern auto)
180°
Low reserve self-start minimum
330°
Overbanking risk threshold
40-60°
Normal DU vs CU spread
📈
Amplitude Decay Calculator
Three modes: Quick (full wind vs current) | Positional (DU vs CU spread) | Multi-Session (full decay curve up to 8 readings). Thresholds: Rotate Watches (2025); H2i.ch (2023); Adjusting Vintage Watches; AWCI.
Movement
Amplitude Readings
Amplitude immediately after fully winding the crown. Record from timegrapher in dial-up (DU) position with correct lift angle set.
Most recent timegrapher reading in the same position (DU). Record at any point during the run-down cycle.
Time between the full wind reading and the current reading. Used to compute the decay rate in degrees per hour.
Movement
Amplitude by Position (at same wind state)
Record timegrapher amplitude for each position at the same wind level (ideally full wind). The positional spread (DU minus best vertical) reveals poise issues, worn pivots, and balance staff damage. Enter DU as minimum; other positions optional.
Movement
Session Readings (hours elapsed + amplitude in DU position)
Enter readings in any order; calculator sorts by hours. First reading should be at full wind (0 hours). Enter up to 8 readings to map the complete amplitude decay curve across the power reserve.
📈

Enter amplitude readings from your timegrapher to instantly compute the decay rate, health zone, overbanking or low-reserve risk, and projected end-of-reserve amplitude.

Amplitude
-°
–
–
Full Wind (°)
–
Total Decay (°)
–
deg/hour
–
% Retained
📈
Calculate to see assessment
Enter amplitude readings and click Calculate.
Full Wind Amplitude
–
Baseline at full mainspring wind
Current Amplitude
–
Latest timegrapher reading
Total Decay
–
Degrees lost from full wind
Decay Rate
–
Average degrees per hour
Amplitude Retained
–
% of full wind remaining
Projected End Amplitude
–
At stated power reserve end
📊 Amplitude Decay Curve and Phase Decay Rate Analysis
Amplitude vs Hours Elapsed (with service threshold lines)
Decay Rate by Phase (deg/hour)

Watch Amplitude: The Single Most Revealing Number on Your Timegrapher Display

Of the three numbers a timegrapher shows you, amplitude is the one that most directly reflects the mechanical health of the entire movement. Rate tells you how fast or slow the balance oscillates. Beat error tells you how symmetrically it oscillates. But amplitude tells you how much energy actually reaches the balance wheel from the mainspring, through every gear, jewel, and pivot in between. A watch with excellent rate and low beat error can still have critical amplitude, and that combination means one thing: the movement is running on borrowed time before it stops. Every problem in the power delivery chain from the mainspring coils to the escape wheel leaves a signature in the amplitude number. Dried lubricants that have thickened or gummed? Amplitude drops. A mainspring that has permanently set and lost elasticity? Amplitude drops. Worn barrel arbor bearings that allow the barrel to cock sideways? Amplitude drops. Damaged pivot jewels in the gear train that increase friction? Amplitude drops. A bent pivot on the third wheel? Amplitude drops in specific positions. The movement on your timegrapher is telling you exactly how healthy its entire power delivery system is, in a single number in degrees.

The Amplitude Formula: How Your Timegrapher Computes the Number

/* AMPLITUDE FORMULA (acoustic measurement) */
/* H2i.ch Glossary (2023); WahaWatches lift angle guide (2022) */
A = (3600 x lift_angle) / (t13 x PI x BPH)

/* Where: */
lift_angle = escape wheel lift angle in degrees (caliber-specific)
t13 = time between 1st and 3rd escapement pulse (seconds)
BPH = beats per hour of the movement

/* Example: ETA 2824, lift_angle=50°, t13=0.0073s, BPH=28800 */
A = (3600 x 50) / (0.0073 x 3.14159 x 28800)
A = 180,000 / 661.1 = 272°

/* AMPLITUDE DECAY RATE: */
decay_rate = (A_initial – A_current) / elapsed_hours /* deg/hr */
pct_retained = (A_current / A_initial) x 100 /* % */

/* PROJECTED END AMPLITUDE (linear extrapolation): */
A_end = A_initial – (decay_rate x power_reserve_hours)
/* Note: Real decay is faster near end of reserve; linear projection is conservative */

Why Amplitude Decreases Across the Power Reserve

A fully wound mainspring delivers its maximum torque output to the barrel wheel and gear train. As the spring uncoils, the torque it can deliver decreases in a roughly exponential fashion. Because the pallet fork requires a minimum amount of torque from the escape wheel to push the balance wheel past its rest position and set it in full oscillation, there is a minimum threshold of mainspring energy below which the balance amplitude drops below the safe operating range. In a well-designed, freshly serviced movement, this threshold is not reached until the last 10 to 20 percent of the power reserve. In a movement with dirty lubricants, a worn mainspring, or damaged gear train components, that threshold may be reached at 60 or 70 percent of the stated power reserve, explaining why a 42-hour watch effectively runs accurately for only 28 or 30 hours before rate accuracy begins to suffer. As Kapoor Watch documented in April 2026, lower amplitude at the end of the power reserve directly causes the watch to run faster in the final hours, because a lower balance arc means the hairspring’s isochronism is tested at smaller amplitudes where its linearization is less precise. This rate variation across the power reserve is the fundamental reason why well-serviced movements with high consistent amplitude keep better time on the wrist than degraded movements with low or rapidly declining amplitude.

Verified US Watchmaking Amplitude Thresholds for Modern and Vintage Movements

Modern Automatic Movements (21,600-28,800 BPH) – Horizontal Positions

Amplitude RangeZoneInterpretationRequired ActionSource
330° and aboveOverbanking RiskPallet fork risks striking opposite banking pin during some oscillationsInspect escapement immediately. Check banking pin clearance.SJX Watches (2020); AWCI escapement training
290 – 329°ExcellentOptimal horizontal amplitude. Clean, efficient power delivery from mainspring to balance.No action. Log as baseline for future comparison.Rotate Watches (Sept 2025); H2i.ch (2023)
270 – 289°GoodNormal healthy range for daily wear. Good energy delivery through the gear train.No action required. Continue monitoring at scheduled service intervals.Rotate Watches (Sept 2025)
250 – 269°AcceptableToward lower end of normal. May indicate early lubricant degradation or partial mainspring set.Note and monitor. Flag for attention at next scheduled service.Rotate Watches (Sept 2025); Adjusting Vintage Watches
220 – 249°LowLubricant degradation, mainspring set, or worn components likely. Rate accuracy may be affected.Service recommended. Full clean-ultrasonic and fresh lubricants likely needed.Adjusting Vintage Watches; H2i.ch (2023)
Below 220°CriticalSeverely degraded power delivery. Watch may stop erratically, especially in vertical positions.Service urgently required. Do not defer. Check mainspring, barrel, and gear train thoroughly.Rotate Watches (Sept 2025); AWCI service standards

Modern Automatic – Vertical Positions (CU, CD, CL, CR)

Amplitude RangeZoneInterpretationAction
250 – 300°ExcellentStrong vertical amplitude. Excellent positional performance expected.No action.
220 – 249°GoodNormal vertical range. 40-60° below horizontal is typical.No action if spread from DU is within 40-60°.
200 – 219°AcceptableAcceptable vertical but on the lower side. Monitor positional rate variation.Note and monitor. Flag at next service if worsening.
180 – 199°LowLow vertical amplitude. Stopping risk at low power reserve in vertical orientation.Service recommended. Check poise and pivot condition.
Below 180°CriticalWatch at risk of stopping in vertical positions, especially near end of power reserve.Service urgently required.

Source: Rotate Watches (September 2025). “Fully wound horizontals commonly read 270 to 310 degrees on modern everyday calibres. Verticals often land 220 to 270 degrees at full wind. A healthy spread from best to worst position often sits around 40 to 60 degrees. Larger gaps hint at friction or poise issues.” Source: rotatewatches.com/blogs/blog/what-is-amplitude-in-mechanical-watch.

Typical Full-Wind Amplitude by Common US Movement Calibers

CaliberBPHTypical Full Wind DULow Reserve DU (est.)Power ReserveSource
ETA 2824-2 / Sellita SW20028,800285-295°220-235°38-40 hrRotate Watches; Crown Vintage
ETA 2892-A228,800285-295°225-240°42 hrCaliberCorner; community reports
Miyota 82-series28,800270-290°200-220°40-42 hrRotate Watches; WatchUSeek
Miyota 901528,800275-290°210-230°42 hrRotate Watches; community data
Seiko NH35 / NH3621,600265-285°195-215°41 hrRotate Watches (2026)
Seiko 6R3521,600275-290°210-230°70 hrSeiko specification; community
Rolex Cal. 313528,800305-320°240-260°48 hrSJX Watches (2020); Crown Vintage
ETA Valjoux 775028,800265-285°200-220°42 hrCommunity bench reports; CaliberCorner
Generic Vintage 18K BPH (pocket)18,000240-270°170-200°30-36 hrAdjusting Vintage Watches; AWCI vintage standards

Note: Actual amplitude varies by individual specimen condition, lubrication state, and mainspring wear. Values shown represent typical ranges for freshly serviced, healthy movements. Sources: Rotate Watches (September 2025); CaliberCorner.com; SJX Watches movement analysis database (2020); Crown Vintage Witschi WAIO testing data (2026); community-reported bench readings on WatchUSeek and r/watchmaking.

Three Real US Watchmaker Scenarios: Diagnosing Amplitude Decay in Practice

📈 Scenario 1 – Watchmaking Student Bench Session, Texas Institute of Jewelry Technology, Paris, Texas

Post-Service Amplitude Verification: ETA 2824-2 After Full Service

A second-year student at the Texas Institute of Jewelry Technology (TIJT), one of the ten AWCI-recognized US watchmaking schools, has completed a full service on an ETA 2824-2 movement: complete disassembly, cleaning in an ultrasonic cleaner, fresh lubricants at all service points per ETA technical guidelines, and reassembly. Before returning the watch to the customer, the student performs a complete multi-position amplitude verification to confirm the service quality meets AWCI standards. The timegrapher is a Witschi Expert with lift angle set to 50° for the ETA 2824.

Movement: ETA 2824-2 | BPH: 28,800 | Lift angle: 50°
Post-service readings at full wind:
Dial Up (DU): 292° – EXCELLENT
Dial Down (DD): 280° – Good
Crown Up (CU): 255° – Good
Crown Left (CL): 248° – Good
Crown Right (CR):251° – Good

Positional spread (DU – best vertical = DU – CU):
292° – 255° = 37° spread – Normal (40-60° typical; 37° is excellent)

After 20 hours (checked next day):
DU amplitude: 261° | Decay: 292-261 = 31° | Rate: 31/20 = 1.55 °/hr
Projected at 40h PR: 292 – 1.55×40 = 230° (within acceptable range)
Excellent results confirming a quality service. DU amplitude of 292° is within the expected 285-295° healthy range for the ETA 2824-2. Positional spread of 37° is below the 40-60° normal range, indicating excellent balance poise and clean pivot bearings. Decay rate of 1.55°/hr is within the normal zone. The projected end-of-reserve amplitude of 230° remains above the 220° service threshold, confirming the mainspring is delivering adequate power across the full power reserve. The student documents all readings in the service record per AWCI professional practice guidelines. The customer receives a complete amplitude verification report with the timepiece.
🚨 Scenario 2 – Independent Watchmaker, Denver, Colorado

Diagnosing Rapid Amplitude Decay: Vintage Hamilton 992B in a Collection

A NAWCC member and private collector in Denver has a cherished Hamilton 992B railroad pocket watch from the 1940s that has been running well by the display but has begun stopping overnight when placed in a vertical position in the watch stand. The collector takes the movement to a local AWCI-certified watchmaker, who places it on a timegrapher immediately after full winding and begins logging amplitude readings every few hours to map the decay curve. The 992B runs at 18,000 BPH.

Movement: Hamilton 992B | BPH: 18,000 | Lift angle: 52°
Multi-session amplitude log (dial up position):
0h: 268° – Full wind baseline (acceptable vintage range)
4h: 248° – Still acceptable, 20° lost
8h: 218° – Low (rapid 50° total drop in 8h)
12h: 185° – Critical – approaching stopping threshold
16h: Watch stopped

Decay analysis:
Overall rate 0-12h: (268-185) / 12 = 6.9 °/hr (VERY HIGH – Critical zone)
Phase 0-4h rate: (268-248) / 4 = 5.0 °/hr
Phase 4-8h rate: (248-218) / 4 = 7.5 °/hr (accelerating – classic mainspring issue)
Phase 8-12h rate: (218-185) / 4 = 8.25 °/hr (further acceleration)

Projected reserve: 268 / 6.9 ≈ 15-16h (stated reserve: 30h)
Stopping: amplitude fell below 160° at approximately 15-16h elapsed
The multi-session decay curve tells an unambiguous diagnostic story. The 992B is losing amplitude at 6.9°/hr overall and the decay rate is accelerating as the watch runs down, a classic pattern of a mainspring that has lost elasticity through decades of use without service and is now delivering progressively less torque per unit of remaining wind. Additionally, the amplitude at full wind (268°) is in the lower part of the acceptable vintage range, suggesting the mainspring is partially set. The watchmaker’s recommendation: full service with mainspring replacement. For a Hamilton 992B, appropriate mainspring dimensions must be sourced from a specialist vintage watch parts supplier (Cousins UK or Esslinger in the US) using the original Hamilton specification. After service with a correct replacement mainspring and fresh lubricants, the 992B should achieve 280°+ at full wind and a 30+ hour power reserve with amplitude remaining above 200° at end of reserve. The NAWCC archival library in Columbia, Pennsylvania, maintains the original Hamilton technical specifications for all 992-series pocket watch movements.
🚨 Scenario 3 – Watch Collector, New York, New York

Overbanking Detection: High Amplitude After Enthusiast Service on a Miyota 9015

A watch enthusiast in New York has serviced their own Miyota 9015 movement for the first time using a hobbyist watchmaking kit. After reassembly, they place the movement on a Weishi 1000 timegrapher set to 28,800 BPH and 49° lift angle (per Miyota spec). They are excited to see what they think is a high amplitude reading, not realizing it indicates a problem rather than excellent performance.

Movement: Miyota 9015 | BPH: 28,800 | Lift angle: 49°
Post-service readings (full wind):
Dial Up (DU): 338° – OVERBANKING RISK ZONE
Crown Up (CU): 312° – High (suspicious for vertical)

Expected healthy range for Miyota 9015 DU:
Healthy full wind: 275-290°
Current reading: 338° (48 degrees ABOVE upper healthy limit)

Overbanking threshold: >= 330°
Assessment: Possible mainspring issue (over-strong or wrong replacement),
pallet fork banking adjustment error, or timegrapher calibration issue
Risk: Pallet fork striking opposite banking pin; escapement lock errors
A DU amplitude of 338° is a warning sign, not a cause for celebration. The Miyota 9015 typically produces 275-290° at full wind in good condition. Readings above 330° indicate the balance wheel is overswinging, meaning the pallet fork may be striking its opposite banking pin on some oscillations, causing irregular locking of the escape wheel and potentially erratic rate or stopping. Possible causes include: an incorrect (over-strong) replacement mainspring installed during the service; a mainspring that has not yet normalized to its working tension immediately after assembly; incorrect banking pin adjustment; or an error in the timegrapher setup (wrong BPH selected, causing an inflated amplitude reading). The hobbyist should first verify the timegrapher settings, then run the watch for 2-3 hours and re-check (some new mainsprings relax slightly). If amplitude remains above 330°, the movement should be examined by an AWCI-certified watchmaker to verify the mainspring specification and escapement banking, because overbanking causes rapid wear to the pallet stones and banking pins, shortening the movement’s service life significantly. The AWCI’s online repair directory at awci.com is the recommended resource for finding a certified watchmaker in the New York metro area.

Six Expert Tips for Tracking Amplitude Decay in US Watchmaking Practice

📈
Tip 1
Always Record Amplitude Before and After Service as Your Professional Baseline

A single amplitude reading at full wind tells you where the movement is now. A before-and-after pair from the same movement at the same wind state tells you what the service accomplished. AWCI-trained watchmakers document pre-service amplitude as standard practice because it establishes the diagnostic baseline (how degraded was the movement when received) and the post-service verification (was the target amplitude range achieved after fresh lubricants and mainspring evaluation). If you receive a movement with 245° amplitude, service it, and it leaves with 287° amplitude, that 42° improvement is objective evidence of the service value. If post-service amplitude is still 245°, the mainspring, barrel arbor bearings, or escapement components require further investigation. As Adjusting Vintage Watches recommends, the target minimum for watches in good mechanical condition is 270° horizontal and 220° vertical; any serviced movement should achieve these benchmarks before leaving the bench.

⛳
Tip 2
Amplitude in Vertical Is More Diagnostic Than Amplitude in Horizontal

While dial-up (DU) amplitude is the standard benchmark position for caliber specifications, crown-up (CU) and crown-down (CD) amplitude tell you more about the movement’s health under the conditions it actually experiences on the wrist. When the crown points up (the most common wrist position during wear for a right-hand wearer), gravity acts on the balance wheel and gear train in a way that exposes any friction increase, poise error, or pivot wear that the horizontal position masks. A movement that reads 285° in DU but only 190° in CU is showing a positional spread of 95°, far above the normal 40-60° range. That gap is a precise diagnostic indicator: values this extreme point to poise errors in the balance wheel (heavy side pulling down under gravity), worn or damaged pivots in the balance staff or gear train, or a bent balance staff causing the balance to run off-axis in vertical orientations. Rotate Watches (September 2025) documented this specifically, noting that positional spread above 60° warrants investigation and spread above 80° strongly suggests service needs that pure rate or horizontal amplitude readings would not reveal.

⏱
Tip 3
Amplitude Decay Rate Reveals the Service Interval More Accurately Than Calendar Time

Watch manufacturers recommend service intervals in calendar time (every 3-5 years for modern automatic watches, every 3-7 years for vintage mechanical watches per AWCI guidelines), but calendar time is a crude proxy for the actual mechanical condition of the movement. A watch worn daily in a humid environment with a rotor spinning frequently develops lubricant degradation much faster than the same model worn occasionally in a controlled indoor environment. Amplitude decay rate gives a direct measurement of how well the movement is preserving its stored energy, independent of calendar time. A modern automatic with a decay rate above 4°/hr at one-third of its power reserve is showing signs of lubricant breakdown or mechanical wear regardless of when it was last serviced. A vintage movement with a decay rate below 2°/hr across its full 30-hour reserve is running cleanly regardless of the date on its last service record. Track amplitude at consistent intervals (say, every 8-12 hours) to build a decay curve for each watch in your collection or service rotation, and use that curve rather than the calendar to determine actual service timing.

🔨
Tip 4
The Lift Angle Setting Directly Affects Your Amplitude Reading

Unlike beat error, which is a direct measurement independent of timegrapher settings, amplitude is a calculated estimate that depends critically on the lift angle entered on the timegrapher. The lift angle is a caliber-specific geometric property of the escapement (the angle the balance wheel rotates while the escape wheel tooth is lifting the pallet stone). Entering the wrong lift angle can cause your amplitude reading to be off by 15-25 degrees or more. For example, the Omega Co-Axial caliber 8500 uses a lift angle of approximately 38°, not the default 52°. Setting the timegrapher to 52° for this movement gives an amplitude reading roughly 18 degrees higher than the true value, potentially masking a low-amplitude condition. The caliber database in this calculator lists the correct lift angle for reference alongside the BPH. For movements not in the database, the manufacturer’s technical specification sheet is the authoritative source. If you cannot locate the specification, the practical check is to mark the balance arm and increase power until the balance just achieves 180°, then adjust the lift angle setting until the timegrapher reads 180°. This calibration method is documented in the WahaWatches lift angle guide (2022) and Escapement.watch (2026).

📚
Tip 5
High Amplitude at Full Wind Does Not Guarantee Good Performance Across the Power Reserve

A common misunderstanding in watch enthusiast communities is that a high amplitude reading at full wind means the watch is in excellent condition overall. Amplitude at full wind is a necessary but insufficient indicator of health. What matters for practical accuracy is how amplitude behaves across the entire power reserve. As Kapoor Watch documented in April 2026, in movements with shorter effective reserves (due to degraded lubricants or a worn mainspring), amplitude drops rapidly in the second half of the reserve, causing the balance to oscillate at increasingly short arcs where the hairspring’s isochronism is less precise, leading to rate variation. The watch may read +2 s/day at full wind and +12 s/day at 75% reserve depletion, appearing to be a well-regulated watch to someone who only checks it after winding. Multi-session amplitude tracking, as supported by this calculator, reveals whether the movement is maintaining adequate amplitude across the full stated power reserve or whether it is effectively running out of power well before the manufacturer’s specification. The comparison of projected end amplitude against the 220° service threshold is the actionable metric for service decisions.

🆕
Tip 6
Vintage American Pocket Watches Need Special Amplitude Consideration

American railroad-grade pocket watches from Hamilton, Waltham, Illinois, Elgin, and Ball running at 18,000 BPH operate with different amplitude expectations than modern wristwatches. Their lower beat frequency means a longer half-period and a different mainspring torque-to-amplitude relationship. Where a healthy ETA 2824 might produce 290° at full wind, a healthy Hamilton 992B or Waltham Model 1908 typically produces 250-270°, and these lower numbers are appropriate and expected for these movements in good condition. AWCI training materials for vintage movement service specify that the minimum acceptable amplitude for a vintage pocket watch in horizontal position after service is 240°, substantially lower than the 270° minimum for a modern automatic. At the same time, amplitude decay rates for vintage pocket watches in original condition may legitimately be higher (4-8°/hr) than for freshly serviced modern movements (1-3°/hr) because vintage movements rarely achieve the lubrication quality of a fresh service and their barrel arbor bearings are often worn. When evaluating a vintage movement, always apply the vintage threshold mode in this calculator and compare the reading not against modern auto benchmarks but against the AWCI and NAWCC vintage movement service standards appropriate for the specific caliber. The NAWCC’s Martin Luther Archival Library at Columbia, Pennsylvania, maintains original factory service manuals for all major American pocket watch manufacturers.

Quick Reference: Amplitude Thresholds, Decay Rates, and Key Formulas

ParameterValue / ThresholdSignificanceSource
Modern auto excellent DU290-329°Optimal horizontal amplitudeRotate Watches (Sept 2025)
Modern auto good DU270-289°Normal healthy rangeRotate Watches (Sept 2025)
Modern auto service thresholdBelow 220° DUService urgently requiredAdjusting Vintage Watches; H2i.ch (2023)
Overbanking riskAt or above 330°Escapement inspection requiredSJX Watches (2020); AWCI training
Low reserve self-start min180° in any positionBelow this, stopping risk at low reserveH2i.ch (2023); Adjusting Vintage Watches
Normal positional spread40-60° (DU minus best vert)Normal healthy variationRotate Watches (Sept 2025)
Elevated positional spread60-80°Check poise and pivotsRotate Watches (Sept 2025)
High positional spreadAbove 80°Service investigation requiredRotate Watches (Sept 2025)
Vintage pocket watch DU acceptable230-270°Normal for 18,000 BPH vintage movementAWCI vintage standards; Adjusting Vintage Watches
Normal decay rate (modern)1.0-2.5°/hrHealthy, freshly serviced movementCommunity bench data; Kapoor Watch (2026)
Elevated decay rate2.5-4.0°/hrEarly lubricant or mainspring degradationKapoor Watch (April 2026)
High decay rate4.0-6.0°/hrService advisable; power delivery impairedde Carle (1965); AWCI service standards
Critical decay rateAbove 6.0°/hrUrgent service requiredAWCI service standards; watchmaking bench practice
Amplitude formulaA = (3600 x lift) / (t13 x PI x BPH)Acoustic timegrapher calculationH2i.ch (2023); WahaWatches (2022)
AWCI service intervalEvery 3-5 years modern; 3-7 years vintageCalendar guideline; amplitude data is betterAWCI.com service recommendations

16 Frequently Asked Questions About Watch Amplitude and Amplitude Decay

What is amplitude in a mechanical watch and why does it matter?+
Amplitude is the angular distance the balance wheel travels in one direction from its rest position before reversing, measured in degrees. A healthy automatic wristwatch movement at full wind typically shows amplitude between 270 and 310 degrees in the horizontal (dial-up) position. Amplitude matters because it directly reflects how much energy from the mainspring successfully reaches the balance wheel through the complete gear train. High and stable amplitude indicates clean, efficient power delivery: fresh lubricants, a healthy mainspring, and unworn pivots and jewels. Low amplitude means energy is being lost somewhere in the power path, most commonly to thickened or dried lubricants, mainspring set or breakage, worn pivot bearings, or escapement friction issues. Amplitude also affects rate accuracy: as documented by Kapoor Watch (April 2026), lower amplitude near the end of the power reserve causes the balance to oscillate at smaller arcs where the hairspring’s isochronism is less precise, causing the watch to gain several seconds per day compared to its fully wound rate. Sources: Rotate Watches (September 2025); H2i.ch glossary (2023); CaliberCorner.com; Kapoor Watch (April 2026).
What is a good amplitude reading for a mechanical watch?+
According to Rotate Watches (September 2025) and standard watchmaking bench practice, a good amplitude for a modern automatic movement (28,800 BPH) at full wind in the dial-up (horizontal) position is 270 to 310 degrees. Excellent amplitude falls in the range of 290 to 329 degrees. Amplitude between 250 and 269 degrees is acceptable but toward the lower end of normal. Amplitude between 220 and 249 degrees is low and warrants attention at the next service. Amplitude below 220 degrees at full wind indicates the movement needs service. For vertical positions (crown-up, crown-left, etc.), good amplitude falls in the 220-249 degree range, with readings above 250 degrees considered excellent and readings below 180 degrees indicating critical condition. For vintage pocket watch movements running at 18,000 BPH, the thresholds are more lenient, with acceptable horizontal amplitude starting at 230 degrees. Note that the correct lift angle must be set on the timegrapher for these numbers to be meaningful, as lift angle directly affects the amplitude calculation. Sources: Rotate Watches (September 2025); Adjusting Vintage Watches; H2i.ch (2023).
What is amplitude decay and why does it happen?+
Amplitude decay is the gradual decrease in balance wheel amplitude as the mainspring runs down from full wind toward the end of the power reserve. It happens because the mainspring delivers progressively less torque as it uncoils, and at lower torque levels, the gear train, escapement, and balance jewels require a larger fraction of the available energy to overcome friction, leaving less energy to maintain the balance wheel oscillation amplitude. In a well-serviced movement with clean lubricants and an unworn mainspring, amplitude decay is gradual and moderate: a modern automatic might lose 50-70 degrees of amplitude across its full 40-hour power reserve, corresponding to a decay rate of roughly 1.5-2 degrees per hour. In a movement with degraded lubricants, the friction at each pivot, barrel arbor, and escapement surface is higher, so the energy cost of overcoming friction takes a larger share of the mainspring’s torque at every level of wind, causing amplitude to drop faster and earlier. This accelerated decay explains why a watch with a stated 42-hour power reserve might actually run accurately for only 28-30 hours before rate variation begins to increase: the amplitude has dropped below the level where the escapement and hairspring work optimally. Sources: de Carle D (1965) Practical Watch Repairing; Kapoor Watch (April 2026); WatchUSeek power reserve forum (2020).
What causes low amplitude in a watch?+
Low amplitude (below 250 degrees at full wind for a modern automatic) is caused by anything that increases friction in the power delivery path or reduces the torque output of the mainspring. The most common causes in US watchmaking practice are: dried, thickened, or absent lubricants at pivot jewels, barrel arbor bearings, or escapement components, which is the expected result of a movement operating beyond its service interval of 3-5 years; mainspring set (permanent deformation of the mainspring steel from repeated winding cycles without service, reducing the spring’s stored energy and torque output); a wrong or undersized replacement mainspring installed during a previous service; worn or cracked pivot jewels that allow the pivot to contact the jewel hole edge rather than floating freely; lateral play (sideshake) in the gear train pivots allowing gear tooth mesh angles to change; barrel arbor bearing wear that allows the barrel to cock sideways and rub against the main plate; hairspring deformation or contact with adjacent coils reducing the effective spring stiffness; escapement friction from worn pallet stones or a damaged roller impulse jewel; or a loose balance wheel causing energy loss through mechanical slip on the balance staff. Sources: Rotate Watches (September 2025); Adjusting Vintage Watches; AWCI training materials; de Carle (1965).
What is the overbanking threshold and what does it mean?+
Overbanking occurs when the balance wheel swings with such high amplitude that the pallet fork travels past its banking pins on both sides alternately, allowing the escape wheel to advance by more than one tooth per balance oscillation rather than the intended one tooth per half-oscillation. The overbanking threshold is generally considered to be approximately 330 degrees of amplitude, though the precise value depends on the specific escapement geometry of the caliber. When overbanking occurs, the movement produces an irregular pattern on the timegrapher trace (sometimes called “galloping”), and the watch may keep poor time, stop unexpectedly, or develop rapid wear on the banking pins and pallet fork. As SJX Watches noted in their movement design analysis (2020), the effective amplitude limit due to overbanking risk is approximately 350 degrees, though practical operation should keep amplitude below 330 degrees to maintain consistent escapement engagement. Causes of overbanking include an over-strong replacement mainspring, an incorrectly adjusted banking pin, or the natural torque spike of a freshly wound mainspring before it settles. If your timegrapher consistently reads above 330 degrees at full wind, have the escapement inspected by an AWCI-certified watchmaker. Sources: SJX Watches (January 2020); Adjusting Vintage Watches; AWCI escapement adjustment training; standard horological engineering.
How does lift angle affect the amplitude reading?+
The lift angle is a caliber-specific geometric property of the escapement that the timegrapher uses to calculate amplitude from the acoustic signal. The timegrapher measures the time between the first and third escapement noise pulses (t13), and uses the formula: Amplitude = (3600 x lift_angle) / (t13 x PI x BPH). If the wrong lift angle is entered, the amplitude reading is proportionally wrong: a lift angle set 5 degrees too high produces an amplitude reading approximately 5 degrees too high. For most modern Swiss movements, 50-52 degrees is correct, so using the default 52-degree setting is usually close enough for general assessment. But for outliers like Omega Co-Axial movements (38 degrees), Breguet’s co-axial adaptations, or some vintage movements with non-standard escapement geometry, the error from a wrong lift angle can be 20-30 degrees, which can cause a movement showing overbanking risk to appear normal, or a critical movement to appear merely low. Always verify the lift angle for the specific caliber before making service decisions based on the amplitude reading. The caliber database in this calculator provides the lift angle for reference alongside the BPH. Source: H2i.ch glossary (2023); WahaWatches (2022); Escapement.watch lift angle guide (April 2026).
How is amplitude decay related to watch accuracy?+
Amplitude affects rate accuracy through the isochronism property of the balance wheel and hairspring system. In a perfectly isochronous oscillator, the period of oscillation (and therefore the rate) would be identical regardless of amplitude. In a real mechanical watch hairspring, small deviations from perfect isochronism mean that the period changes slightly as amplitude changes, typically causing the watch to run slightly faster at lower amplitude. This is why most mechanical watches gain time at low power reserve: the amplitude has dropped to a level where the hairspring’s isochronism deviation becomes significant enough to produce a measurable rate change. As Kapoor Watch documented in April 2026, a movement with shorter effective power reserve (due to rapid amplitude decay) will show greater rate variation across the day than a freshly serviced movement that maintains high amplitude across the full reserve. Modern movement designs attempt to minimize this effect through hairspring geometry (Breguet overcoil, Phillips terminal curve, Beuche-Girod), free-sprung balances (Glucydur), and high beat frequencies (28,800 BPH provides more oscillation averaging). The practical implication for collectors: a watch that keeps perfect time when freshly wound but drifts as the day progresses may be experiencing amplitude-related rate variation and would benefit from a service to restore consistent amplitude across the power reserve. Sources: Kapoor Watch (April 2026); SJX Watches isochronism deep-dive (December 2025); de Carle (1965).
What is positional amplitude spread and what does an abnormal spread indicate?+
Positional amplitude spread is the difference in amplitude between the highest-reading position (usually dial-up or dial-down) and the lowest-reading position (usually a vertical position such as crown-up or crown-down). In a healthy movement, this spread is typically 40 to 60 degrees. A spread below 40 degrees indicates excellent positional consistency, usually seen in freshly serviced movements with well-poised balance wheels. A spread above 60 degrees indicates elevated positional variation, which can point to balance wheel poising issues (uneven mass distribution around the balance axis), worn or damaged balance staff pivots that allow the balance to run off-center under gravity, or gear train pivot wear that increases friction in specific orientations. A spread above 80 degrees is generally considered to require service investigation, as documented by Rotate Watches (September 2025): “A healthy spread from best to worst position often sits around 40 to 60 degrees. Larger gaps hint at friction or poise issues.” For any watch that stopped or shows rate anomalies after a shock (dropping the watch), checking the positional amplitude spread is the most efficient way to detect a bent balance staff pivot, as this damage typically creates a dramatic increase in spread (100 degrees or more) between horizontal and the most affected vertical position. Sources: Rotate Watches (September 2025); Crown Vintage timegrapher guide (2026); standard AWCI bench diagnostic protocol.
How often should a mechanical watch be serviced?+
The American Watchmakers-Clockmakers Institute (AWCI) recommends mechanical watch service intervals of every 3 to 5 years for modern automatic movements and every 3 to 7 years for vintage mechanical watches, as a general calendar-based guideline. However, the AWCI also emphasizes that the actual condition of the movement, as assessed by timegrapher readings including amplitude, beat error, and rate, is a better guide to service timing than calendar time alone. A modern automatic with excellent amplitude (290° or above at full wind), a normal decay rate (under 2.5°/hr), and stable rate can comfortably extend beyond 5 years between services in controlled conditions. A watch worn daily in humid or polluted environments, or one that has received shocks or magnetic exposure, may need service within 2-3 years regardless of the calendar. The multi-session amplitude tracking feature of this calculator gives a data-driven basis for service decisions. When the projected end-of-reserve amplitude drops below 220° based on the current decay curve, or when the decay rate exceeds 4°/hr at mid-reserve, service is warranted regardless of when the last service was performed. For vintage movements, AWCI guidelines recommend not exceeding 5 years between services under any circumstances due to the degradation characteristics of older mainspring alloys. Source: AWCI service recommendations (awci.com); NAWCC collector resources; de Carle (1965).
Can amplitude be too high as well as too low?+
Yes, amplitude can be problematically high as well as low. The overbanking risk threshold at approximately 330 degrees represents the upper practical limit. Above this level, the balance wheel’s impulse jewel can cause the pallet fork to swing past its banking pin on the opposite side during some oscillations, allowing the escape wheel to advance by two tooth pitches instead of one. This produces irregular timekeeping, an erratic trace on the timegrapher, and accelerated wear to the banking pins and pallet stones. Overbanking can result from an over-strong replacement mainspring installed during service, a mainspring that produces a short torque spike at full wind before settling to a normal operating level, or an incorrectly adjusted escapement banking (banking pins positioned too close together, allowing the fork excessive travel). Some watchmakers deliberately allow slightly elevated amplitude (up to 320-325 degrees) immediately after a new mainspring is installed, because new mainsprings often relax by 5-10 degrees of amplitude during the first 2-3 days of running. If amplitude remains above 330 degrees after this break-in period, the mainspring specification should be verified and the escapement banking should be inspected by an AWCI-certified watchmaker. Source: SJX Watches movement design analysis (January 2020); Adjusting Vintage Watches; AWCI escapement training.
What is a normal amplitude for a Rolex, versus an ETA 2824, versus a Seiko NH36?+
Different movements are designed to operate at different amplitude levels based on their escapement geometry, balance inertia, and mainspring specification. The Rolex Cal. 3135, based on community and industry testing data compiled by SJX Watches (2020) and Crown Vintage (2026), typically reads 305-320 degrees at full wind in the dial-up position, reflecting Rolex’s high-quality finishing, generous mainspring torque specification, and well-designed shock resistance. The ETA 2824-2 and Sellita SW200 typically read 285-295 degrees at full wind per Rotate Watches (September 2025) and CaliberCorner data, in line with their 38-40 hour power reserve. The Seiko NH35 and NH36 at 21,600 BPH typically read 265-285 degrees, which reflects the different power-to-frequency tradeoff at their lower beat rate. A reading that is 20-30 degrees below the typical range for a specific caliber is as meaningful as the absolute number, because it indicates the movement is not delivering its intended amplitude. Conversely, a Seiko NH36 reading 320 degrees might appear impressive but could indicate overbanking risk. The caliber database in this calculator provides the typical healthy range for each listed movement to allow comparison of your actual reading against the expected value for the specific caliber you are testing. Source: SJX Watches (2020); Rotate Watches (September 2025); Crown Vintage (2026); CaliberCorner.com.
How does amplitude relate to power reserve duration?+
Amplitude and power reserve are related but distinct properties of a movement. The stated power reserve is the manufacturer’s specification for how long the movement will run from fully wound to stopping, measured in hours. Amplitude is a real-time indicator of how much energy is being delivered to the balance wheel at any given moment of the reserve cycle. They intersect when amplitude drops below the minimum threshold for reliable operation, which is approximately 160-180 degrees depending on the movement type. The watch stops when the mainspring’s remaining torque is insufficient to push the pallet fork through the escapement cycle and set the balance in oscillation. A freshly serviced movement with clean lubricants maintains adequate amplitude right to the end of its rated power reserve, stopping sharply only when the mainspring is nearly fully uncoiled. A movement with degraded lubricants or worn components runs out of effective amplitude (drops below 180 degrees) well before the theoretical end of the mainspring’s energy, effectively shortening the functional power reserve even though the mainspring itself still has energy. This is why a watch rated at 42 hours might run accurately for only 28-30 hours before rate variation becomes significant, and might stop at 32-35 hours rather than 42. Multi-session amplitude tracking reveals this discrepancy and quantifies the actual functional reserve versus the rated reserve. Source: Kapoor Watch (April 2026); WatchUSeek power reserve forum; de Carle (1965).
Does winding a watch manually vs automatic winding affect amplitude?+
In a well-functioning automatic movement, both hand winding through the crown and automatic winding through the rotor should bring the mainspring to the same full-wind state and produce the same amplitude. However, in some movements with rotor slippage, a worn or damaged clicking mechanism, or a weak rotor that does not engage fully during typical wrist motion, automatic winding may not bring the mainspring to full tension. In this case, hand winding may produce noticeably higher amplitude (sometimes 15-25 degrees higher) than the amplitude after a day of normal wear, revealing that the rotor or automatic winding mechanism is not delivering full power to the mainspring. If you notice that your amplitude reading after a full day of active wear is significantly lower than the reading after hand winding to the click, the automatic winding mechanism (rotor bearing, clicking spring, reduction gears, or coupling mechanism) should be inspected. This comparison is best made using this calculator’s Quick mode: record amplitude after full hand-winding as the baseline, then re-test after a full day of wear and note the difference. A difference of more than 20-25 degrees in the same position suggests an automatic mechanism issue. Source: Standard watchmaking practice; AWCI automatic movement service guidelines; Crown Vintage (2026).
What is the difference between balance wheel amplitude and pendulum amplitude in clock movements?+
Balance wheel amplitude and pendulum amplitude are analogous concepts in watch and clock movements respectively, but they are measured differently and have different practical significance. In a mechanical watch, the balance wheel is a torsional oscillator controlled by a hairspring; its amplitude is measured in degrees of rotation and is typically 220-330 degrees for a healthy movement. In a pendulum clock, the pendulum is a gravitational oscillator; its amplitude is measured in degrees of arc from vertical, typically 2-8 degrees for a household pendulum clock. The key operational difference is that a pendulum clock’s period (and therefore rate) is much more sensitive to amplitude changes than a watch’s balance wheel, because the pendulum’s isochronism deviation is larger at normal operating amplitudes. A balance wheel hairspring system, when properly designed and adjusted, achieves relatively good isochronism across its normal operating amplitude range. A pendulum is isochronous only for extremely small amplitudes (the small-angle approximation), which is why precision pendulum clocks are designed to operate with minimal amplitude variations. For NAWCC members restoring pendulum clocks, amplitude measurement is typically done with a protractor or by timing the pendulum period at two different amplitudes and noting the period difference. This calculator is specifically designed for balance wheel amplitude in mechanical watch movements, not pendulum clocks. Source: Daniels G (2011) Watchmaking; de Carle D (1959) Practical Clock Repairing; NAWCC technical library.
What resources does AWCI provide for US watchmakers regarding amplitude standards?+
The American Watchmakers-Clockmakers Institute (AWCI), headquartered in Harrison, Ohio, provides several resources relevant to amplitude assessment and service standards. The Marvin E. Whitney Academy of Watchmaking at the AWCI facility offers hands-on courses in basic quartz watch repair, modern automatic watches, balance staffing and timing, and advanced movement service. These courses include timegrapher training covering amplitude, beat error, and rate measurement, with AWCI-standard benchmarks for acceptable readings at each stage of service. AWCI publishes Horological Times, the only monthly horological trade magazine in the US, which regularly features technical articles on movement service including amplitude-related topics. The AWCI’s technical advice line and online member forum provide professional guidance on specific movement service questions including amplitude diagnosis. For vintage American pocket watch service, AWCI’s library of technical materials and its connection with the NAWCC archival library at Columbia, Pennsylvania, provide access to original factory service specifications for Hamilton, Waltham, Illinois, Elgin, and other American movement manufacturers. AWCI also operates the largest online repair directory for consumers seeking certified watchmakers, searchable at awci.com. The CW21 (Certified Watchmaker for the 21st Century) examination, which is the primary US professional credential, includes competency requirements in timegrapher use and movement regulation that encompass amplitude assessment. Source: AWCI.com (2024-2025); Wikipedia: American Watchmakers-Clockmakers Institute.
How do I use multi-session tracking to decide when to service a watch?+
Multi-session amplitude tracking for service decision-making works as follows. After fully winding the watch, place it on the timegrapher in dial-up position and record the full-wind amplitude (this is reading 1 at hour 0). Continue wearing or storing the watch normally. After 8-10 hours, take another reading in the same position (reading 2). After another 8-10 hours (16-20 hours total), take a third reading (reading 3). If you can take a fourth reading near the end of the rated power reserve, this gives the most complete picture. Enter all readings into the Multi-Session mode of this calculator. The calculator will show you the overall decay rate (degrees per hour), the rate in each phase (which can reveal whether decay is linear or accelerating), and the projected amplitude at the rated power reserve end. Use these decision rules: if the decay rate is below 2.5°/hr throughout and the projected end amplitude is above 220°, the movement does not need immediate service by amplitude criteria alone; if the decay rate is 2.5-4.0°/hr or the projected end amplitude is 180-220°, schedule service within the next 12 months; if the decay rate exceeds 4.0°/hr, the projected end amplitude falls below 180°, or the decay curve is accelerating (getting faster in later phases), service is due now regardless of the calendar date. Source: AWCI service guidelines; standard watchmaking bench practice; Kapoor Watch (April 2026).

Related Horology Hub and Precision Tools

Amplitude is one of three essential timegrapher readings. These Horology Hub tools cover the complete movement assessment toolkit for US watchmakers and collectors.

Verified Sources and References
Amplitude thresholds: Rotate Watches (September 2025); H2i.ch Glossary of Watchmaking Terms (2023); Adjusting Vintage Watches; SJX Watches movement design analysis (January 2020). Decay rate: Kapoor Watch (April 2026); de Carle D (1965) Practical Watch Repairing. Caliber data: community bench data; Crown Vintage Witschi WAIO testing (2026); CaliberCorner.com. Formula: H2i.ch (2023); WahaWatches (2022). US standards: AWCI (awci.com); NAWCC (nawcc.org); HSNY (hsny.org). SJX isochronism (December 2025).