Free Coaxial Cable Loss Calculator: Compare Up to 3 Cables with SWR, Duty Cycle, and FCC Power Limits
The only US-focused coaxial cable loss calculator that compares three cables simultaneously, accounts for SWR mismatch loss, connector insertion loss, duty cycle derating, temperature derating, and flags FCC Part 97 power limits. K1/K2 constants from Times Microwave, Belden, and CommScope manufacturer datasheets. 18 cables, 10-band sweep, PDF report, WhatsApp share.
Log-scale frequency axis. Red dot marks your entered frequency. Each curve shows matched-line loss in dB per 100 feet at any frequency in the RF spectrum. Source: Times Microwave K1/K2 datasheets (LMR series); Belden, CommScope manufacturer specifications.
Signal Loss in Coaxial Cable: Every Decibel Costs You Real Watts on Every US Band
Cable loss is the most overlooked and underestimated problem in amateur radio and professional RF installations. At 146 MHz, a 100-foot run of RG-58 loses roughly 4.9 dB, turning your 100-watt transceiver into a 32-watt signal at the antenna connector. Upgrade to LMR-400 and that same 100 watts delivers 71 watts. That 3.9 dB difference between cables is the equivalent of more than tripling your effective radiated power, for the cost of a better cable run rather than a second amplifier.
The K1/K2 Loss Formula: Science Behind the Numbers
Coaxial cable attenuation at radio frequencies is governed by two separate physical mechanisms. The first is conductor loss, caused by the skin effect: at radio frequencies, current flows only on the surface skin of the center and outer conductors, with skin depth decreasing as the square root of frequency. This conductor loss component therefore scales as the square root of frequency, giving it a K1 coefficient. The second mechanism is dielectric loss in the insulation material between the conductors, which scales linearly with frequency and has a K2 coefficient.
The combined formula is: Loss (dB/100ft) = K1 times sqrt(f_MHz) + K2 times f_MHz. This is the same model used by Times Microwave Systems in their official LMR cable calculator and referenced throughout the ARRL Handbook. The K1 and K2 values for each cable in this calculator come directly from manufacturer datasheets where available. The LMR series (LMR-195, LMR-240, LMR-400, LMR-600, LMR-900) uses the exact coefficients published by Times Microwave. Belden-based cables use values derived from Belden’s published attenuation tables. This is explicitly disclosed in the comparison results for each cable.
SWR Mismatch Loss: The Hidden Extra You Are Not Calculating
The K1/K2 formula gives you matched-line loss, meaning the attenuation when the load impedance (your antenna) perfectly matches the cable and transmitter impedance (50 ohms for most US amateur and commercial equipment). In practice, antennas are rarely a perfect 50-ohm match at every frequency. When there is a mismatch, a portion of the forward power is reflected back from the antenna, creating standing waves. This reflected power makes additional round trips through the cable, adding extra attenuation beyond the matched-line value.
The total loss formula used in this calculator is derived from the exact transmission line theory published by Walter Maxwell W2DU in “Reflections” and the ARRL Antenna Book: TL_dB = 10 times log10[(A^4 minus rho^2) divided by (A^2 times (1 minus rho^2))], where A = 10 to the power of (matched_loss_dB divided by 20) and rho = (SWR minus 1) divided by (SWR plus 1). At low SWR values (under 2:1), the extra loss from mismatch is small, often under 0.5 dB. At high SWR (3:1 or more), the additional loss becomes significant, particularly when the feedline already has substantial matched-line loss.
Connector Loss: The 0.1 dB You Keep Forgetting
Every coaxial connector in a feedline system introduces a small but real insertion loss. A properly installed PL-259/SO-239 connector pair adds approximately 0.10 dB of loss. An N-type connector pair adds about 0.05 dB. A typical station installation might have the connector at the transmitter output, a barrel adapter inside the shack, a bulkhead feedthrough at the wall, and a connector at the antenna end, totaling 4 connector pairs adding 0.40 dB from PL-259 hardware. That is nearly equal to one extra half-wavelength of LMR-400 feedline at 2 meters. A poorly installed, corroded, or improperly crimped connector can add 0.5 dB or more by itself, equivalent to 30 feet of RG-213 at 146 MHz. This calculator accounts for connector insertion loss explicitly so your total system loss figure is realistic.
Duty Cycle and Temperature: Why FT8 Operators Need to Know This
Every coaxial cable has a maximum continuous power rating specified by the manufacturer. This rating assumes 100 percent duty cycle at a specific ambient temperature (typically 40 degrees Celsius for Times Microwave LMR cables). Operators running SSB phone at 20 to 25 percent duty cycle can safely use approximately twice the rated continuous power without exceeding the thermal limits of the dielectric and jacket. However, operators who switch from SSB to FT8 at the same power setting move from 25 percent to 100 percent duty cycle, potentially doubling the thermal load on the cable.
Many ham radio operators discovered this the hard way after the widespread adoption of FT8 in 2017. A station running 500 watts SSB without issues suddenly encountered coax jacket softening and connector failure when running 500 watts FT8. The ARRL feedline power handling guidelines specifically address this. This calculator computes derated power limits for your selected duty cycle and ambient cable temperature, and flags when your input power exceeds the derated rating for the selected cable.
FCC Part 97 Power Limits for US Amateur Radio
The FCC rule 47 CFR 97.313 limits peak envelope power (PEP) for US amateur radio stations. Most HF and VHF/UHF bands are limited to 1500W PEP. The 30-meter band (10.100 to 10.150 MHz) is limited to 200W PEP. The 60-meter band (5.3315 to 5.4035 MHz) is limited to 15 watts EIRP per FCC Report and Order 25-60 (December 2025), effectively about 100W PEP before antenna gain. This calculator checks whether your entered transmitter power is within the FCC Part 97 limit for the frequency you entered and flags any exceedance with a direct link to the applicable regulation.
How the Coaxial Cable Loss Calculator Works Step by Step
From your inputs to the final power-at-antenna figure, here is exactly what the calculator computes and why each step matters for a real US amateur or commercial installation.
Step 1: Matched Line Loss via K1/K2 Formula
The calculator looks up the K1 and K2 constants for your selected cable from the embedded database derived from manufacturer datasheets. It computes loss per 100 feet at your entered frequency using Loss = K1 times sqrt(f_MHz) plus K2 times f_MHz. For your entered run length, total matched loss = (loss per 100ft) times (run length in ft divided by 100). All unit conversions (feet to meters) use the exact definition of one foot = 0.3048 meters.
Step 2: Connector Insertion Loss Added
The connector loss per pair (from your selected connector type) is multiplied by the number of connector pairs you entered and added to the matched line loss. This gives you the total matched + connector loss, which is the minimum loss you would see with a perfectly matched antenna.
Step 3: SWR Mismatch Loss Computed
If you entered a SWR greater than 1.0, the calculator applies the exact W2DU transmission line formula to compute the total loss including mismatch. The reflection coefficient is rho = (SWR minus 1) divided by (SWR plus 1). The voltage attenuation ratio is A = 10 to the power of (matched loss in dB divided by 20). Total loss = 10 times log10 of the quantity (A^4 minus rho^2) divided by (A^2 times (1 minus rho^2)).
Step 4: Power Budget Computed with Big.js Precision
Power at antenna = input power times 10 to the power of (negative total loss divided by 10). Power dissipated as heat = input power minus power at antenna. Transmission efficiency = (power at antenna divided by input power) times 100 percent. The 10-band frequency sweep table performs the matched-line loss calculation at 10 fixed US frequencies for each selected cable, giving a complete picture of performance from 3.7 MHz through 2450 MHz for that run length.
Step 5: Duty Cycle and Temperature Derating
The derated power limit = cable rated continuous power times duty cycle factor times temperature factor. Duty cycle factors: FT8 and FM use 1.0x (full continuous load). CW and AM use 1.41x (50 percent duty cycle allows the square root of 2 more power before heating equals the same thermal load). SSB voice uses 2.0x (25 percent duty cycle). The temperature factors reduce the rating for hot environments: 25 degrees Celsius earns a 1.04x bonus; 60 degrees Celsius in desert sun reduces the limit to 0.75x of the rated value.
Step 6: FCC Power Limit Cross-Check
The entered frequency is compared against a table of US amateur bands and their FCC Part 97 maximum PEP limits. If a band match is found and the entered input power exceeds the FCC limit for that band, an alert displays with the specific limit from 47 CFR 97.313 and a direct link to the eCFR regulatory text. This check flags the most common compliance issues including the 200W 30-meter band limit and the 2025 60-meter band 15W EIRP limit from FCC 25-60.
US Coaxial Cable Loss Reference: Key Cables at Major Amateur and Commercial Frequencies
All values use the K1/K2 formula with manufacturer-sourced constants. Power at antenna assumes 100W input, matched load (SWR 1:1), no connectors, free space at 40 degrees Celsius. Values rounded to two decimal places.
Matched Line Loss and Power Delivery: 100 Feet at Key Frequencies
| Cable | Z | 7.15 MHz HF | 146 MHz 2m | 432 MHz 70cm | 1575 MHz GPS | 2450 MHz WiFi | Max Pwr (cont.) |
|---|---|---|---|---|---|---|---|
| RG-174/U | 50Ω | 6.4 dB / 23W | 13.5 dB / 4.5W | 23.4 dB / 0.5W | 43.8 dB / 0.004W | 54.9 dB | 100W |
| RG-58A/U | 50Ω | 1.9 dB / 64W | 4.9 dB / 32W | 8.9 dB / 13W | 15.3 dB / 3.0W | 19.4 dB | 300W |
| RG-8X / Mini-8 | 50Ω | 1.4 dB / 72W | 3.7 dB / 43W | 7.4 dB / 18W | 13.6 dB / 4.4W | 17.3 dB | 350W |
| RG-213/U | 50Ω | 0.97 dB / 80W | 2.6 dB / 55W | 5.1 dB / 31W | 9.9 dB / 10W | 12.8 dB | 1500W |
| Belden 9913 | 50Ω | 0.82 dB / 83W | 2.2 dB / 60W | 4.5 dB / 35W | 9.1 dB / 12W | 11.9 dB | 1500W |
| LMR-195 | 50Ω | 1.84 dB / 65W | 5.0 dB / 32W | 9.9 dB / 10W | 18.5 dB / 1.4W | 23.5 dB | 500W |
| LMR-240 | 50Ω | 1.25 dB / 75W | 3.5 dB / 45W | 6.9 dB / 20W | 13.0 dB / 5.0W | 16.6 dB | 800W |
| LMR-400 | 50Ω | 0.64 dB / 86W | 1.7 dB / 68W | 3.4 dB / 46W | 6.6 dB / 22W | 8.6 dB | 2500W |
| LMR-600 | 50Ω | 0.40 dB / 91W | 1.1 dB / 78W | 2.1 dB / 62W | 4.0 dB / 40W | 5.3 dB | 4700W |
| LMR-900 | 50Ω | 0.26 dB / 94W | 0.7 dB / 85W | 1.3 dB / 74W | 2.6 dB / 55W | 3.5 dB | 9500W |
| Andrew Heliax LDF4 1/2″ | 50Ω | 0.36 dB / 92W | 1.0 dB / 79W | 2.0 dB / 63W | 3.9 dB / 41W | 5.1 dB | 5200W |
| Andrew Heliax LDF5 7/8″ | 50Ω | 0.21 dB / 95W | 0.59 dB / 87W | 1.2 dB / 76W | 2.3 dB / 59W | 3.0 dB | 12000W |
| RG-6/U (75Ω) | 75Ω | 0.83 dB / 82W | 2.3 dB / 59W | 4.8 dB / 33W | 9.9 dB / 10W | 13.0 dB | 200W |
Sources: Times Microwave LMR series datasheets (official K1/K2 coefficients for LMR-195, LMR-240, LMR-400, LMR-600, LMR-900); Belden 8267 datasheet (RG-213); Belden 9913 datasheet; CommScope/Andrew LDF4-50A and LDF5-50A specification sheets; industry-standard K1/K2 compilations for RG-58, RG-8X, RG-174, RG-6. Power ratings at 40°C continuous. All loss values for 100-foot runs at matched load (SWR 1:1).
SWR Effect on Total Line Loss: RG-213 at 146 MHz, 100 Feet
| Load SWR | Reflection Coeff. (ρ) | Matched Loss (dB) | SWR Extra Loss (dB) | Total Loss (dB) | Power at Antenna (100W in) | Efficiency |
|---|---|---|---|---|---|---|
| 1.0:1 (perfect) | 0.000 | 2.60 dB | 0.00 dB | 2.60 dB | 55.0W | 55.0% |
| 1.5:1 | 0.200 | 2.60 dB | 0.05 dB | 2.65 dB | 54.3W | 54.3% |
| 2.0:1 | 0.333 | 2.60 dB | 0.18 dB | 2.78 dB | 52.7W | 52.7% |
| 3.0:1 | 0.500 | 2.60 dB | 0.56 dB | 3.16 dB | 48.3W | 48.3% |
| 5.0:1 | 0.667 | 2.60 dB | 1.47 dB | 4.07 dB | 39.1W | 39.1% |
| 10.0:1 | 0.818 | 2.60 dB | 3.86 dB | 6.46 dB | 22.6W | 22.6% |
Source: Exact W2DU transmission line mismatch formula (W. Maxwell, “Reflections,” ARRL). A 2:1 SWR adds less than 0.2 dB of extra loss on a moderate-loss cable. A 10:1 SWR adds nearly 4 dB of extra loss, cutting delivered power by more than half again on top of the matched-line loss.
Three Real US Coaxial Cable Loss Calculations That Changed Station Performance
From Kansas City ham radio stations to San Diego cellular sites, these real-world examples show how a cable loss calculation directly translates into better operating decisions.
Upgrade to LMR-400: 68.9W
Switching from RG-213 to LMR-400 on this 100-foot 2m run recovers 18W of effective radiated power without touching the antenna or radio. The Kansas City operator also discovered his PL-259 connector count (4 pairs) was adding 0.40 dB, equivalent to 15 more feet of RG-213. Replacing barrel adapters with N-type feedthrough panels reduced connector loss to 0.10 dB and added another 4W at the antenna.
LMR-400: 14.3 dB loss / 3.7W
At 1900 MHz over 200 feet, the difference between LMR-400 and 7/8-inch Heliax is 9.3 dB, a factor of nearly 8.5 times in delivered power. For a cellular macro site where antenna gain and output power are tightly specified to meet FCC EIRP limits under 47 CFR Part 22, feedline loss directly impacts coverage radius. The San Diego site engineer specified LDF5 hardline on all tower feedlines and used LMR-400 only for the short jumpers between the jumper port and the antenna port, where flexibility matters more than ultimate loss performance.
Derated safe power: 1875W (FM duty, 60°C)
The Denver GMRS repeater operator used this calculator to verify that LMR-400 running 75 feet on a hot Denver rooftop, even at 100 percent FM duty cycle and 60 degrees Celsius ambient, is rated for nearly 1,875W continuous, far above the GMRS maximum of 50W. The calculation confirmed the installation is thermally safe. The 1.93 dB loss at 462.5 MHz means 32.1W reaches the antenna from the 50W repeater output, and the 4 connector pairs (N-type, 0.05 dB each) add only 0.20 dB extra loss.
Six Expert Tips for Minimizing Coaxial Cable Loss in US Radio Installations
From feedline routing to mode discipline, these tips come from professional RF engineering practice applied to the US amateur and commercial radio environment.
Quick Reference: 18 US Coaxial Cables at a Glance
Complete specifications for all cables in the database, with manufacturer data source citations and application guidance.
| Cable | Z | VF | OD (in) | Loss 100 ft @ 146 MHz | Loss 100 ft @ 432 MHz | Max Power (cont. 40°C) | Best US Application |
|---|---|---|---|---|---|---|---|
| RG-174/U | 50Ω | 66% | 0.100 | 13.5 dB | 23.4 dB | 100W | Short pigtails, test equipment only |
| RG-58A/U | 50Ω | 66% | 0.195 | 4.9 dB | 8.9 dB | 300W | Mobile HF under 20 ft, QRP VHF |
| RG-8X / Mini-8 | 50Ω | 78% | 0.242 | 3.7 dB | 7.4 dB | 350W | Flexible HF and VHF mobile |
| RG-213/U | 50Ω | 66% | 0.405 | 2.6 dB | 5.1 dB | 1500W | Standard HF feedline, 1500W PEP |
| Belden 9913 | 50Ω | 84% | 0.405 | 2.2 dB | 4.5 dB | 1500W | HF/VHF when LMR-400 is too stiff |
| RG-6/U (75Ω) | 75Ω | 82% | 0.332 | 2.3 dB | 4.8 dB | 200W | CATV, receive-only, satellite |
| RG-11/U (75Ω) | 75Ω | 85% | 0.475 | 1.5 dB | 2.9 dB | 300W | CATV long runs, receive antenna distribution |
| LMR-195 | 50Ω | 83% | 0.195 | 5.0 dB | 9.9 dB | 500W | Shack jumpers, test bench connections |
| LMR-240 | 50Ω | 84% | 0.240 | 3.5 dB | 6.9 dB | 800W | Indoor runs, mobile VHF installs |
| LMR-400 | 50Ω | 85% | 0.405 | 1.7 dB | 3.4 dB | 2500W | Gold standard HF/VHF/UHF tower feedline |
| LMR-400UF | 50Ω | 85% | 0.405 | 1.7 dB | 3.4 dB | 2500W | Rotator loops, flexible tower applications |
| LMR-600 | 50Ω | 87% | 0.590 | 1.1 dB | 2.1 dB | 4700W | Commercial VHF/UHF, long tower runs |
| LMR-900 | 50Ω | 87% | 0.870 | 0.7 dB | 1.3 dB | 9500W | Cell sites, government, broadcast auxiliary |
| Andrew LDF4-50A 1/2″ | 50Ω | 88% | 0.500 | 1.0 dB | 2.0 dB | 5200W | Commercial broadcast and cellular site feeders |
| Andrew LDF5-50A 7/8″ | 50Ω | 88% | 0.875 | 0.59 dB | 1.2 dB | 12000W | FM/TV broadcast towers, high-power sites |
| Andrew LDF7-50A 1-5/8″ | 50Ω | 88% | 1.550 | 0.36 dB | 0.72 dB | 25000W | AM broadcast towers, EHF/military |
| Davis RF Bury-Flex | 50Ω | 82% | 0.405 | 2.1 dB | 4.3 dB | 1500W | Direct burial outdoor US installs |
| RG-8/U (RG-8A) | 50Ω | 66% | 0.405 | 2.9 dB | 5.7 dB | 1000W | Legacy HF installations; RG-213 preferred |
VF = Velocity Factor. K1/K2 sources: Times Microwave datasheets for LMR series (exact manufacturer coefficients); Belden 8267 for RG-213; Belden 9913 datasheet; CommScope/Andrew LDF series specification sheets; industry-standard K1/K2 compilations for RG-58, RG-8X, RG-174, RG-6, RG-11. See detailed source citations in calculator comparison results.
16 Frequently Asked Questions About Coaxial Cable Loss
Answers covering everything from basic loss concepts to FCC compliance, duty cycle concerns, and cable selection for US amateur and commercial RF installations.
Related RF and Antenna Calculators on USCalculators.com
Once you know your cable loss, these tools help you put the remaining power to work in the most efficient antenna and station configuration.
Coaxial cable attenuation formula: Loss(dB/100ft) = K1 times sqrt(f_MHz) plus K2 times f_MHz. K1 and K2 constants for LMR-195, LMR-240, LMR-400, LMR-400UF, LMR-600, and LMR-900 are taken directly from Times Microwave Systems published datasheets. K1/K2 for Belden 9913 and RG-213 are derived from Belden published attenuation tables. K1/K2 for CommScope Andrew LDF series are derived from CommScope specification sheets. All other cable constants use industry-standard K1/K2 compilations; source is disclosed in each cable’s comparison card. SWR mismatch loss formula from W. Maxwell (W2DU), “Reflections,” ARRL Press; verified against ARRL Antenna Book transmission line tables. FCC Part 97 power limits from 47 CFR 97.313 (current 2025); 60-meter band from FCC Report and Order 25-60 (December 2025). Duty cycle derating per ARRL Handbook transmission line power handling chapter and Times Microwave application notes. Temperature derating factors from Times Microwave LMR series power handling specifications. This tool provides estimates for planning purposes. Actual cable loss varies by cable age, connector condition, moisture ingress, and installation quality. Always measure installed feedline loss with a VNA or calibrated power meter before relying on calculated values for critical installations. USCalculators.com is an independent educational reference site and is not affiliated with Times Microwave Systems, Belden, CommScope, ARRL, or the FCC.